    Flowmeter for the continuous measurement of water

    Type 8081 / Ident No. 560613

    Compare now Print
    Produkt-Foto Typ 8081

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8081
    • Produkt-Foto Typ 8081
    • Massbild
    • Massbild
    • Massbild
    • Massbild

    Flow sensor without display

    • Ultrasonic flowmeter using transit time method
    • Dynamic range ≥ 1:250
    • Low pressure drop
    • No flow-settling section necessary in the inlet or outlet

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Product description

    The Type 8081 ultrasonic flowmeter is intended for the flow measurement of water which may be slightly charged with contaminants. It consists of an electronic module and a brass fitting with a built-in measuring tube. In combination with a controller and a control valve, it enables very simple flow control loops to be established. The electrical connection is made via a 5 pin M12 fixed connector. The flowmeter features, depending on the version: - a pulse output or - a pulse output and a 4…20 mA current output. Each version is available for 5 different flow ranges: - model QN 0.6 DN15: 0.06 to 20 l/min (nominal flow rate 0.6 m3/h namely 10 l/min) - model QN 1.5 DN15: 0.1 to 50 l/min (nominal flow rate 1.5 m3/h namely 25 l/min) - model QN 2.5 DN20: 0.16 to 82 l/min (nominal flow rate 2.5 m3/h namely 41 l/min) - model QN 3.5 DN25: 0.6 to 116 l/min (nominal flow rate 3.5 m3/h namely 58 l/min) - model QN 6.0 DN25: 1 to 200 l/min (nominal flow rate 6.0 m3/h namely 100 l/min)


    Commodity Codes
    90261021
    Country
    FR

    Technical attributes

    Name
    Value
    Unit
    Type 8081
    Product sub-group Flow rate
    Flow rate (volume) Yes
    Concentration No
    Continuous measurement Yes
    Dosing No
    Switch Yes
    Construction device Compact
    Display type no display
    Protection class measurement device (IP) IP65
    DC voltage min. 12 V
    DC voltage max. 36 V
    Battery voltage No
    Precision of volume flow rate in relation to reading 1 %
    Temperature environment min 5 °C
    Temperature environment max 55 °C
    Temperature medium min 5 °C
    Temperature medium max 90 °C
    Pressure Class (PN) PN 16
    Dynamic viscosity min. 0 cP
    Dynamic viscosity max. 10 cP
    Min measured value of volume flow rate 0.1
    Max measured value of volume flow rate 50
    Measured value unit l/min
    Detection of flow direction Yes
    Sensor type Ultrasound
    Cable plug in delivery not included
    Electrical connection 1 type Plug - M12
    Electrical connection 1 quantity 1 PCE
    Electrical connection 1 number of contacts 5 PCE
    Electrical connection 1 gender male
    Electrical connection 1 material category Plastics
    Electrical connection 1 material PA (Polyamide)
    Electrical connection 1 seal material EPDM (Ethylene-propylene-diene rubber)
    Output 1 digital type Transistor
    Output 1 digital version NC No
    Output 1 digital version NO No
    Output 1 digital transistor connection NPN Yes
    Output 1 digital transistor connection PNP No
    Digital output 1 transistor contactless 0.7 A
    Electronics body material category Plastics
    Electronics body material PPS (Polyphenylene sulphide)
    Cover material PPS (Polyphenylene sulphide)
    Seal housing/cover material Silicone
    Screw material Stainless steel
    Electronics body encapsulated Resin
    Parametrisation local No
    Parametrisation separate No
    Parametrisation fixed Yes
    Diameter measuring tube (DN) 15 mm
    Fluidic port connection number 2
    Port connection 1 type Outer thread
    Port connection 1 thread type NPT
    Port connection 1 thread marking 3/4
    Port connection 2 type Outer thread
    Port connection 2 thread type NPT
    Port connection 2 thread marking 3/4
    Port connection material category Metals
    Port connection material Brass
    Measuring pipe material PES (Polyethersulfone)
    Medium-contacting parts seal material EPDM (Ethylene-propylene-diene rubber)
    Installation length 110 mm
    Weight 0,700000 kg
    Show full table Collapse table

    Downloads

    Data Sheets

    Description
    Filesize
    Language / Country
    DTS Type 8081 data sheet | Ultrasonic flowmeter without display 713 kB EN / EU
    DTS Typ 8081 Datenblatt | Ultraschall-Durchflussmessgerät für Wasser 714 kB DE / DE
    DTS Type 8081 fiche technique | Débitmètre à ultrasons pour l'eau 709.7 kB FR / FR

    User Manuals

    Description
    Filesize
    Language / Country
    MAN Operating Instructions Type 8081 | Ultrasonic flowmeter without display 635 kB EN / EU
    MAN Bedienungsanleitung Typ 8081 | Ultraschall-Durchfluss-Transmitter ohne Display 724.9 kB DE / EU
    MAN Manuel d'utilisation Type 8081 | Transmetteur de débit à ultrason sans écran 637.8 kB FR / EU

    EU Declaration

    Description
    Filesize
    Language / Country
    ABD EU-DoC|EU Declaration 767.8 kB ML

    Interactive Animation

    Description
    Filesize
    Language / Country
    3D_ANIMATION 3D-Animation - 8081 3.8 MB DE
    3D_ANIMATION 3D-Animation - 8081 3.7 MB EN

    My Comparison List