bürkert
We make ideas flow.
We make ideas flow.

    pH/ORP meter

    Type 8202 / Ident No. 559632

    Produkt-Foto Typ 8202

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8202
    • Produkt-Foto Typ 8202
    • Produkt-Foto Typ 8202
    • Produkt-Foto Typ 8202
    • Ersatzteil-Zeichnung Bürkert

    8202 - without electrode nut PVDF 1XM12

    • Integral compact measurement device for direct connection to control level (PLC)
    • Thanks to the modular HMI, parameterization, calibration, transferring of parameterization data easily possible
    • Usage of 120 mm standard PG13,5 pH/ORP-probes with S8 connector (Type 8203 recommended)
    • Simulation of process value and diagnostic function

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Product description

    The Bürkert Type 8202 is a compact, but modular device, specially designed for measuring the pH or ORP value of fluids. Our device consists of a replaceable standard 120 mm pH or ORP probe, screwed in a sensor holder with integrated Pt1000 temperature sensor. This ensemble is plugged-in and screwed with a nut to an IP67 enclosure containing the electronic module with cover and a removable display. Bürkert expedites thus maintenance work. The pH/ORP transmitter can operate independent of the display, but it will be required for programming the device (i.e. selection of pH or ORP sensor type, measuring range, engineering units...) and also for visualizing continuously the measured and processed data. The device Type 8202 is available : - with three fully programmable outputs : two transistor and one 2-wire 4-20 mA current outputs - with four fully programmable outputs: two transistor and two 3-wire 4-20 mA current outputs The device Type 8202 converts the measured signal, displays different values in different units (if display mounted) and computes the output signals, which are provided via one or two M12 fixed connectors.


    Commodity Codes
    90278011
    Country
    FR

    Technical attributes

    Name
    Value
    Unit
    Type 8202
    PH Yes
    Conductivity conductive No
    Conductivity inductive No
    ORP Yes
    Chlorine total No
    Chlorine free No
    Chlorine dioxide No
    Oxygen No
    Turbidity No
    Temperature Yes
    Ozone No
    Neutrino variant No
    Construction device Compact
    Display type no display
    Protection class measurement device (IP) 65/67
    DC voltage min. 14 V
    DC voltage max. 36 V
    Operating supply type 2 conductor
    Measured value min -2 m
    Measured value max 16 m
    Measured value unit pH
    Measured value min 2 -2000
    Measured value max 2 2000
    Measured value unit 2 mV
    Measuring accuracy 1 0.02
    Unit of measuring accuracy 1 PH
    Measuring accuracy 2 3
    Unit of measuring accuracy 2 mV
    Measuring accuracy temperature (°C) 1 °C
    Temperature environment min -10 °C
    Temperature environment max 60 °C
    Temperature medium min -20 °C
    Temperature medium max 130 °C
    Pressure Class (PN) PN 16
    Temperature compensation Yes
    Fitting connection type F002 Inner thread
    Fitting connection thread G
    Fitting connection thread marking 1 1/2
    Cable plug in delivery not included
    Electrical connection 1 type Plug - M12
    Electrical connection 1 quantity 1 PCE
    Electrical connection 1 number of contacts 5 PCE
    Electrical connection 1 gender male
    Electrical connection 1 material Diecast zinc, nickel-plated
    Electrical connection 1 seal material NBR (Nitrile rubber)
    Output analogue current functioning principle source Yes
    Output analogue current functioning principle drain Yes
    Output 1 type analog current 4-20 mA
    Output 1 digital type Transistor
    Output 1 digital transistor connection NPN Yes
    Output 1 digital transistor connection PNP Yes
    Digital output 1 transistor contactless 0.7 A
    Output 2 digital type Transistor
    Output 2 digital transistor connection NPN Yes
    Output 2 digital transistor connection PNP Yes
    Digital output 2 transistor contactless 0.7 A
    Electronics body material Stainless steel
    Cover material PPS (Polyphenylene sulphide)
    Protection lid material PC (Polycarbonate)
    Nut material PVDF (Polyvinylidene fluoride)
    Seal sensor/housing material EPDM (Ethylene-propylene-diene rubber) food-quality
    Seal housing/cover material EPDM (Ethylene-propylene-diene rubber)
    Protection lid seal material EPDM (Ethylene-propylene-diene rubber) food-quality
    Electrical connection plate material Stainless steel
    Screw material Stainless steel
    Electronics body encapsulated Without
    Tropical climate version Yes
    Finger material PVDF (Polyvinylidene fluoride)
    Parametrisation local Yes
    Parametrisation separate No
    Parametrisation fixed No
    Weight 1,100000 kg
    Weight 1,100000 kg
    Show full table Collapse table

    Downloads

    Description
    Filename
    Filesize
    Language / Country
    3D_ANIMATION 3D-Animation - 8202 3D-PDF-DE-SA-ORPD3_pdf.pdf 3.8 MB DE
    3D_ANIMATION 3D-Animation - 8202 3D-PDF-EN-SA-ORPD3_pdf.pdf 3.8 MB EN
    3D_ANIMATION 3D-Animation - 8202 3D-PDF-DE-SA-PHD2_pdf.pdf 3.9 MB DE
    3D_ANIMATION 3D-Animation - 8202 3D-PDF-EN-SA-PHD2_pdf.pdf 3.9 MB EN
    ABD EU-DoC|EU Declaration 1000292044-0_8202_EU-DoC signed.pdf 467.9 kB ML
    DTS pH- oder O.R.P. Transmitter DS8202-Standard-DE-DE.pdf 672.1 kB DE / DE
    DTS pH- or O.R.P. Transmitter DS8202-Standard-EU-EN.pdf 670.7 kB EN / EU
    DTS Transmetteur pH Redox DS8202-Standard-FR-FR.pdf 670.7 kB FR / FR
    DTS pH- or O.R.P. Transmitter DS8202-Standard-US-EN.pdf 979.3 kB EN / US
    DTS Transmisor pH o ORP estándar DS8202-Transmitter-ES-ES.pdf 2.1 MB ES / ES
    DTS pH oder ORP Transmitter DS8202-neutrino-DE-DE.pdf 853.7 kB DE / DE
    DTS Transmisor pH o ORP neutrino DS8202-neutrino-ES-ES.pdf 1.8 MB ES / ES
    DTS pH or ORP Transmitter DS8202-neutrino-EU-EN.pdf 856.8 kB EN / EU
    DTS Transmetteur de pH ou ORP DS8202-neutrino-FR-FR.pdf 853.7 kB FR / FR
    DTS pH o. ORP Sonden DS8203-standard-DE-DE.pdf 1.7 MB DE / DE
    DTS pH or ORP probe DS8203-standard-EU-EN.pdf 1.7 MB EN / EU
    DTS Sonde de pH ou potentiel Redox DS8203-standard-FR-FR.pdf 1.7 MB FR / FR
    DTS INSERTION Adapter DSS022-standard-DE-DE.pdf 915.5 kB DE / DE
    DTS INSERTION Adaptor for Analysis DSS022-standard-EU-EN.pdf 915.5 kB EN / EU
    MISC Flyer Element and Element neutrino Analytical Meters Types 8202, 8222, 8228 587.3 kB EN / EU
    MAN GasketSet - ConnectingBox MA8202-GasketBox-EU-ML.pdf 140.3 kB EN,FR,DE / EU
    MAN Mounting Gasket on holder MA8202-GasketSet-EU-ML.pdf 132.3 kB EN,FR,DE / EU
    MAN Bedienungsanleitung 8202 MA8202-Manual-EU-DE.pdf 3.6 MB DE / EU
    MAN Operating Instructions 8202 MA8202-Manual-EU-EN.pdf 3.6 MB EN / EU
    MAN manuel d'utilisation 8202 MA8202-Manual-EU-FR.pdf 3.6 MB FR / EU
    MAN Quickstart 8202/8222 MA8202-Quickstart-EU-ML.pdf 6.2 MB EN,FR,DE / EU
    MAN neutrino pH redox transmitter MA8202-neutrino-EU-ML.pdf 5.8 MB EN,FR,DE / EU
    MAN neutrino pH redox transmitter MA8202-neutrino-EU-ML.pdf 5.8 MB EN,FR,DE / EU
    MAN pH and Redox probes MA8203-pHRedoxProbe-EU-ML.pdf 348.2 kB EN,FR,DE / EU
    MAN Operating Instruction Display MA8222-Manual-EU-ML.pdf 808.8 kB EN,FR,DE / EU
    Position
    Item No.
    Description
    438680 Plug M12 5 positions 2m screened
    Position
    Item No.
    Description
    01 561843
    02 559169