Bürkert - Close to you
Office /2
    • Main Office
      Burkert Middle East FZE
      Ras al Khaimah | United Arab Emirates

      Phone +971 7207 6696
      Fax +971 7207 6695
      E-Mail fnyrf.nr@ohexreg.pbz
    • Distributor
      Daly Fluid Technologies LLC – DFT
      Dubai | United Arab Emirates
      Phone +971 4887 8185
      Fax +971 4887 8184
      E-Mail fnyrf@qsgzr.pbz
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
We make ideas flow.
We make ideas flow.

    Inductive conductivity meter

    Type 8228 / Ident No. 566605

    Produkt-Foto Typ 8228

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8228
    • Produkt-Foto Typ 8228
    • Produkt-Foto Typ 8228
    • Produkt-Foto Typ 8228

    Inductive conductivity transmitter

    • Perfect for concentrated liquids and wide conductivity range
    • Pre-parameterized versions available for direct start-up
    • Integral device for direct connection to PLC
    • Simulation of process values for diagnostics
    • Sensor available in PEEK, PVDF or PP

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Product description

    Bürkert’s inductive conductivity meter type 8228 is designed for usage under harsh conditions in many industrial processes for measuring in concentrated liquids like acids, caustics or salt-solutions over a wide measuring range. Applications like cooling water monitoring (i.e. dilution control), industrial water treatment or preparation and identification of cleaning liquids for example in CIP processes. The device is available in two models: - the first is the standard version with a G 2” process connection to be mount in Type S020 fitting - the second is the CIP version with a Clamp 2” process connection according to ASME BPE (Clamp 1.5” on request).

    Commodity Codes

    Technical attributes

    Type 8228
    PH No
    Conductivity conductive No
    Conductivity inductive Yes
    ORP No
    Chlorine total No
    Chlorine free No
    Chlorine dioxide No
    Oxygen No
    Turbidity No
    Temperature Yes
    Ozone No
    Construction device Compact
    Display type Display module
    Protection class measurement device (IP) 65/67
    DC voltage min. 12 V
    DC voltage max. 36 V
    Operating supply type 3 conductor
    Measuring accuracy 1 2
    Unit of measuring accuracy 1 %
    Measuring accuracy temperature (°C) 1 °C
    Temperature environment min -10 °C
    Temperature environment max 60 °C
    Temperature medium min -15 °C
    Temperature medium max 130 °C
    Pressure Class (PN) PN 10
    Temperature compensation Yes
    Fitting connection type Outer thread
    Fitting connection thread G
    Fitting connection thread marking 2
    Electrical connection 1 type Plug - M12
    Electrical connection 1 quantity 1 PCE
    Electrical connection 1 number of contacts 5 PCE
    Electrical connection 1 gender male
    Electrical connection 1 material Diecast zinc, nickel-plated
    Electrical connection 1 seal material NBR (Nitrile rubber)
    Output analogue current functioning principle source Yes
    Output analogue current functioning principle drain Yes
    Output 1 type analog current 4-20 mA
    Output 1 digital type Transistor
    Output 1 digital transistor connection NPN Yes
    Output 1 digital transistor connection PNP Yes
    Digital output 1 transistor contactless 0.7 A
    Electronics body material Stainless steel
    Cover material PPS (Polyphenylene sulphide)
    Protection lid material PC (Polycarbonate)
    Nut material PC (Polycarbonate)
    Seal sensor/housing material EPDM (Ethylene-propylene-diene rubber) food-quality
    Seal housing/cover material EPDM (Ethylene-propylene-diene rubber)
    Protection lid seal material EPDM (Ethylene-propylene-diene rubber) food-quality
    Electrical connection plate material Stainless steel
    Screw material Stainless steel
    Electronics body encapsulated Without
    Tropical climate version Yes
    Medium-contacting parts seal material FKM (Fluor rubber)
    Finger material PEEK (Polyetheretherketone)
    Parametrisation local Yes
    Parametrisation separate No
    Parametrisation fixed No
    Weight 1,040000 kg
    Weight 1,040000 kg
    Show full table Collapse table


    Language / Country
    3D_ANIMATION 3D-Animation - 8228 3D-PDF-DE-SA-8228_pdf.pdf 4 MB DE
    3D_ANIMATION 3D-Animationen - 8228 3D-PDF-EN-SA-8228_pdf.pdf 4.1 MB EN
    ABD EU-DoC|EU Declaration 1000292046-0_8228_EU-DoC signed.pdf 468.5 kB ML
    DTS Induk. Leitfähigkeitsmessgerät DS8228-Standard-DE-DE.pdf 795.6 kB DE / DE
    DTS Inductive conductivity meter DS8228-Standard-EU-EN.pdf 795 kB EN / EU
    DTS Conductimètre inductif DS8228-Standard-FR-FR.pdf 795.4 kB FR / FR
    DTS Fitting für Insertion-Sensor DSS020-Standard-DE-DE.pdf 401.1 kB DE / DE
    DTS Fitting for insertion Sensor DSS020-Standard-EU-EN.pdf 402.9 kB EN / EU
    DTS Raccord à insertion DSS020-Standard-FR-FR.pdf 400.4 kB FR / FR
    MISC Flyer Element and Element neutrino Analytical Meters Types 8202, 8222, 8228 587.3 kB EN / EU
    MAN Operating Instruction Display MA8222-Manual-EU-ML.pdf 808.9 kB EN,FR,DE / EU
    MAN Bedienungsanleitung 8228 MA8228-Manual-EU-DE.pdf 2.6 MB DE / EU
    MAN Operating Instructions 8228 MA8228-Manual-EU-EN.pdf 2.6 MB EN / EU
    MAN Manuel d'utilisation 8228 MA8228-Manual-EU-FR.pdf 2.5 MB FR / EU
    MAN Quickstart 8228 MA8228-Quickstart-EU-ML.pdf 3.3 MB EN,FR,DE / EU
    Item No.
    438680 Plug M12 5 positions 2m screened