    Type 8012 / Ident No. 556017

    Produkt-Foto Typ 8012

    The depiction of the products may differ from the actual specific design.

    • Produkt-Foto Typ 8012
    • Produkt-Foto Typ 8012
    • Produkt-Foto Typ 8012
    • Massbild
    • Massbild
    • Massbild
    • Massbild
    • Ersatzteil-Zeichnung Bürkert

    Flow sensor

    • Economic integration in pipe systems without any additional piping
    • Measuring principle: optic or magnetic
    • Programmable output: 1 analog 4-20 mA and/or 1 transistor output (frequency or switch)
    • Outputs programmable (through interface on USB port with PC)

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Product description

    The paddle-wheel flow sensor for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids in its magnetic measuring version and for use in liquids which let pass the infra-reds in its optic measuring version. The sensor is made up of a fitting (Type S012) and an electronic module (Type SE12) connected together with screws. The Bürkert designed fitting system ensures simple installation of the sensor into all pipes from DN06 to DN50. It can also be installed in fluid block systems. The sensor produces a programmable frequency pulse signal, proportional to the flow rate, which can easily be transmitted and processed by a Bürkert remote transmitter/indicator (type8025/8032), or a programmable switch output or a 4-20 mA signal.


    Commodity Codes
    90261021
    Country
    FR

    Technical attributes

    Name
    Value
    Unit
    Type 8012
    Flow rate (volume) Yes
    Continuous measurement Yes
    Dosing No
    Switch Yes
    Display type no display
    Protection class measurement device (IP) 67
    DC voltage min. 12 V
    DC voltage max. 36 V
    Battery voltage No
    Operating supply type 3 conductor
    Precision of volume flow rate in relation to reading 1 %
    Temperature environment min -15 °C
    Temperature environment max 60 °C
    Temperature medium min -15 °C
    Temperature medium max 100 °C
    Pressure Class (PN) PN 16
    Dynamic viscosity min. 0 cP
    Dynamic viscosity max. 300 cP
    Min measured value of volume flow rate 2163
    Max measured value of volume flow rate 72106
    Measured value unit l/h
    Detection of flow direction Yes
    Sensor type Paddle wheel
    Paddle wheel type Optical
    Paddle wheel measuring principle detection Infrared
    Cable plug in delivery not included
    Electrical connection 1 type Plug - M12
    Electrical connection 1 quantity 1 PCE
    Electrical connection 1 number of contacts 5 PCE
    Electrical connection 1 gender male
    Electrical connection 1 material PA (Polyamide)
    Electrical connection 1 seal material EPDM (Ethylene-propylene-diene rubber)
    Output type analog quantity 1 PCE
    Output analogue current functioning principle source No
    Output analogue current functioning principle drain Yes
    Output type analog sinus No
    Output type current modulated according to NAMUR No
    Output 1 type analog current 4-20 mA
    Output 1 digital type Transistor
    Output 1 digital version NC No
    Output 1 digital version NO No
    Output 1 digital transistor connection NPN Yes
    Output 1 digital transistor connection PNP No
    Digital output 1 transistor contactless 0.7 A
    Electronics body material PPS (Polyphenylene sulphide)
    Seal housing/cover material EPDM (Ethylene-propylene-diene rubber)
    Screw material Stainless steel
    Parametrisation local No
    Parametrisation separate No
    Parametrisation fixed Yes
    Diameter measuring tube (DN) 50 mm
    Fluidic port connection number 2 PCE
    Port connection 1 type Inner thread
    Port connection 1 thread type G
    Port connection 1 thread marking 2
    Port connection material Brass
    Measuring pipe material Brass
    Armature material PVDF (Polyvinylidene fluoride)
    Medium-contacting parts seal material FKM (Fluor rubber)
    Paddle wheel material PVDF (Polyvinylidene fluoride)
    Paddle wheel axle material Ceramic
    Bearing material Ceramic
    Installation length 148.5 mm
    Weight 2,000000 kg
    Weight 2,000000 kg
    Show full table Collapse table

    Downloads

    Description
    Filename
    Filesize
    Language / Country
    ABD EU-DoC|EU Declaration 1000293238-0_8012_EU-DoC signed.pdf 470.2 kB ML
    DTS Sensor de caudal DS8012-Standard-ES-ES.pdf 984.3 kB ES / ES
    DTS Capteur de débit DS8012-Standard-FR-FR.pdf 1.3 MB FR / FR
    DTS Flow Sensor DS8012-Standard-US-EN.pdf 2.1 MB EN / US
    DTS Durchflusssensor DS8012-standard-DE-DE.pdf 1.6 MB DE / DE
    DTS Flow sensor DS8012-standard-EU-EN.pdf 1.3 MB EN / EU
    MAN Sensor de caudal de paletas MA8012-Flowpaddle-ES-ES.pdf 694.4 kB ES / ES
    MAN Bedienungsanleitung 8011 MA8012-Manual-EU-DE.pdf 2.1 MB DE / EU
    MAN Operating Instructions 8012 MA8012-Manual-EU-EN.pdf 2.1 MB EN / EU
    MAN Manuel d'utilisation 8012 MA8012-Manual-EU-FR.pdf 2.1 MB FR / EU
    SOW 8012 Configuration B.01 Setup-TACT-B.01-08.10.12.zip 16.8 MB
    Position
    Item No.
    Description
    438680 Plug M12 5 positions 2m screened
    Position
    Item No.
    Description
    01 557065
    02 555775